The FPC PTFE Coated Fabric range includes products for both architectural (4, 6 & 9 micron glass fiber yarn based) and industrial (6 & 9 micron glass fiber yarn based) applications.
The fine glass yarns are woven into woven fabric on the latest and most advanced weaving machines and coated with PTFE in a series of passes on the state-of-the-art coating towers.
APPLICATIONS
|
Transportation Facilities
|
Airports, Railway & Bus terminals
|
Sport Facilities
|
Multi-purpose Stadiums, Gymnasiums, Race Tracks, Swimming pools etc.,
|
Commercial Facilities
|
Exhibition / Convention centers, Shopping malls / Food courts, Warehouses, Car park shades, Hotels & resorts, Marine / Aquarium facilities, etc.,
|
Institutional Facilities
|
College / Universities, Hospitals, Museums, Walkways etc.
|
Industrial Facilities
|
Factories, Warehouses, Treatment plants etc.,
|
Cultural Facilities
|
Amphitheaters, Plays / Enactments Tents etc.,
|
TYPICAL PROPERTIES*
|
|
|
TYPE
|
WP
|
Type I
|
Type I
|
Type II
|
Type III
|
Type IV
|
Type II
|
Type III
|
Type IV
|
PRODUCT
|
M1000
|
M1001
|
M1002
|
M1003
|
M1004
|
M1005
|
M4001
|
M4002
|
M4003
|
Support Cloth
|
EC9
|
EC6
|
EC6
|
EC6
|
EC6
|
EC6
|
EC3
|
EC3
|
EC3
|
Base Fabric Weight (g/m2)
|
600
|
300
|
400
|
500
|
650
|
750
|
400
|
500
|
650
|
Coating Type
|
PTFE
|
PTFE
|
PTFE
|
PTFE
|
PTFE
|
PTFE
|
PTFE
|
PTFE
|
PTFE
|
Top Coat
|
-
|
FEP
|
FEP
|
FEP
|
FEP
|
FEP
|
FEP
|
FEP
|
FEP
|
Total Coated Fabric Weight (g/m2)
|
800
|
660
|
850
|
1150
|
1380
|
1600
|
800
|
1250
|
1550
|
Nominal Thickness (mm)
|
0.8
|
0.41
|
0.50
|
0.7
|
0.8
|
0.95
|
0.55
|
0.8
|
1.0
|
Breaking Strength (N/5cm)
Warp
Weft
|
5200
5000
|
4000
3500
|
5500
5000
|
6000
5000
|
8000
7000
|
8750
8300
|
4200
4000
|
7000
6000
|
8000
7000
|
Trapezoidal Tear (N) Warp Weft
|
600
450
|
244
267
|
333
355
|
500
500
|
600
550
|
711
800
|
300
300
|
500
500
|
650
800
|
Adhesion (N/5cm)
|
-
|
60
|
79
|
88
|
88
|
88
|
60
|
80
|
100
|
SOLAR PROPERTIES
|
|
|
|
|
|
|
|
|
|
Translucency (%) (nom.)
|
-
|
21
|
19
|
15
|
13
|
10
|
20
|
14
|
9
|
Reflection (%)
|
-
|
70
|
80
|
73
|
74
|
74
|
74
|
78
|
73
|
THERMAL PROPERTIES
|
|
|
|
|
|
|
|
|
|
Thermal Transmittance
U-Value (W/m2K)
|
-
|
5.6
|
5.6
|
5.6
|
5.6
|
5.6
|
5.6
|
5.6
|
5.6
|
Solar factor (g)
|
-
|
0.22
|
0.21
|
0.19
|
0.16
|
0.16
|
0.21
|
0.17
|
0.16
|
Shading Coefficient (b)
|
-
|
0.27
|
0.26
|
0.24
|
0.20
|
0.2
|
0.26
|
0.21
|
0.2
|
FIRE PROPERTIES
|
|
|
|
|
|
|
|
|
|
ASTM E84
|
Class I
|
Class I
|
Class I
|
Class I
|
Class I
|
Class I
|
Class I
|
Class I
|
Class I
|
ASTM E108 / NFPA 701
|
Pass
|
Pass
|
Pass
|
Pass
|
Pass
|
Pass
|
Pass
|
Pass
|
Pass
|
DIN 4102 Part 1
|
A2
|
A2
|
B1
|
B1
|
B1
|
B1
|
B1
|
B1
|
B1
|
* All mechanical test values shown above are based on DIN Standards. These values are for use as indication only.